Viktiga specifikationer
Punkt: Specifications
PFHD: Refer to the following table(Note: (Probability of dangerous failure per hour) depends on number of single beam sensorST4-A□connected to controller.)
MTTFD: More than 100 years (Note:Mean time to dangerous failure (in years))
Vikt: Net weight: 180 g approxGross weight: 390 g approx
Leverantörsinformation
PANASONIC
PANASONIC
Produkter: 4316
Skickas vanligtvis inom 2-3 arbetsdagar
Kvalitetsgaranti
Snabb leverans
Teknisk support

Tekniska specifikationer

Parameter Värde
Punkt Specifications
PFHD Refer to the following table(Note: (Probability of dangerous failure per hour) depends on number of single beam sensorST4-A□connected to controller.)
MTTFD More than 100 years (Note:Mean time to dangerous failure (in years))
Vikt Net weight: 180 g approxGross weight: 390 g approx
Detaljer Controller
Produkt Compact Type 4 Safety Beam Sensor
Material Enclosure: ABS
Artikelnummer ST4-C11
Produktnamn Compact Type 4 Safety Beam Sensor ST4
Kabeldragning Terminal block connector: 0.2 to 1.5 mm2
Spänning 24 V DC +10-15 % Ripple P-P 10 % or less
Svarstid OFF response: 25 ms or lessON response: 90 ms or less (auto reset) / 140 ms or less (manual reset)
Produktnummer ST4-C11
Hjälputgångar PNP open-collector transistor / NPN open-collector transistor (Set using output polarity selection switch)ST4-C11: one outputST4-C12EX: four outputs[PNP output]Maximum source current: 100 mAApplied voltage: same as the supply voltage (between auxiliary output and +V)Residual voltage: 2.5 V or less (at 100 mA source current)[NPN output]Maximum sink current: 100 mAApplied voltage: same as the supply voltage (between auxiliary output and 0 V)Residual voltage: 2.0 V or less (at 100 mA sink current)(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less.
Utgång för ljuddämpningslampa -(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less.
Anslutningsterminal Detachable spring-cage terminal
Nuvarande förbrukning 100 mA or less (excluding sensor head ST4-Ax)
Tillämpliga standarder IEC 61496-1/2 (JIS B 9704-1/2 / UL 61496-1/2) (Type 4), ISO 13849-1:2015 (Category 4, PLe), JIS B 9705-1 (Category 4), IEC 61508-1 to 3 (SIL3), IEC 62061 (SIL3), JIS C 0508-1 to 3 (SIL3), UL 1998, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI/RIA R15.06, ANSI/ISA S84.01 (SIL3)(Note) Complies with those standards only when the controller is used in combination with the sensor head ST4-x.
Tillämpligt sensorhuvud ST4-Ax
Överensstämmelse med CE-märkningsdirektivet Machinery Directive, EMC Directive, RoHS Directive
Hjälputgångar: Driftläge OFF when all beams of the connected ST4-Axs are receivedON when one or more beams of the connected ST4-Axs are interrupted
Styrutgångar (OSSD 1, OSSD 2) PNP open-collector transistor / NPN open-collector transistor Dual output x 1 system (Set using output polarity selection switch)[PNP output]Maximum source current: 200 mAApplied voltage: same as the supply voltage (between control output and +V)Residual voltage: 2.5 V or less (at 200 mA source current)Leakage current: 200 micro A or less (including power OFF condition)Maximum load capacity: 1 micro F (from no-load to max. source current)Load wiring resistance: 3 Ohm or less (between control output and load)[NPN output]Maximum sink current: 200 mAApplied voltage: same as the supply voltage (between control output and 0 V)Residual voltage: 2.0 V or less (at 200 mA sink current)Leakage current: 200 micro A or less (including power OFF condition)Maximum load capacity: 1 micro F (from no-load to max. sink current)Load wiring resistance: 3 Ohm or less (between control output and load)(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less.
Hjälputgångar: Skyddskrets Incorporated
Utgång för ljuddämpningslampa: Skyddskrets Incorporated
Miljöbeständighet: Omgivande luftfuktighet 30 to 85 % RH, Storage: 30 to 95 % RH
Miljöbeständighet: Stötdämpning 300 m/s2acceleration in X, Y and Z directions three times each
Miljöbeständighet: Omgivningstemperatur -10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158℉
Miljöbeständighet: Skyddsgrad Enclosure: IP40 (IEC)Terminal: IP20 (IEC)
Miljöbeständighet: Vibrationsbeständighet 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude or maximum acceleration 90 m/s2 in X, Y and Z directions for two hours each<
Miljöbeständighet: Isoleringsmotstånd 20 MOhm or more with 500 V DC mega between all supply terminals connected together and enclosure
Styrutgångar (OSSD 1, OSSD 2): Driftläge ON when all beams of the connected ST4-Axs are receivedOFF when one or more beams of the connected ST4-Axs are interruptedOFF during lockout
Tillämpligt sensorhuvud: Antal seriekopplingar Interference prevention possible when up to a maximum of 6 sets are connected(When the maximum of 3 controllers are connected together, interference prevention is possible for up to 18 sets)
Styrutgångar (OSSD1, OSSD2): Skyddskrets Incorporated
Miljöbeständighet: Spänningsbeständighet 1,000 V AC for one min. between all supply terminals connected together and enclosure

Produktbeskrivning