Servicetider: måndag till fredag ​​9:00-18:00
UHLC21C - UHLC21C HL-C21C PANASONIC Control unite HL-C2, high resolution, -5 to +5V, 4-20mA, NPN, Ethernet, Export Con..
I lager Het produkt

UHLC21C

UHLC21C HL-C21C PANASONIC Control unite HL-C2, high resolution, -5 to +5V, 4-20mA, NPN, Ethernet, Export Con..

$0.00 USD
i lager
Viktiga specifikationer
Punkt: Specifications
Vikt: 450 g approx.
Detaljer: Controllers(Ethernet communications port)
Produkt: Ultra High-speed- High-precision Laser Displacement Sensor
Leverantörsinformation
PANASONIC
PANASONIC
Produkter: 4316
Skickas vanligtvis inom 2-3 arbetsdagar
Kvalitetsgaranti
Snabb leverans
Teknisk support

Tekniska specifikationer

Parameter Värde
Punkt Specifications
Vikt 450 g approx.
Detaljer Controllers(Ethernet communications port)
Produkt Ultra High-speed- High-precision Laser Displacement Sensor
Material Case: Polycarbonate
Åtföljande USB cable (2 m 6.562 ft long): 1 pc.Short bracket: 1 pc.Ferrite cores (E04SR200935A, by Seiwa Electric Mfg. Co., Ltd.): 3 pcs
Artikelnummer HL-C21C
Återställ ingång NPN open-collector transistor- Reset is done when connected to Common (-).- Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
Larmutgång NPN open-collector transistor- Maximum sink current: 100 mA- Applied voltage: 30 V DC or less [between each output and Common(-)]- Residual voltage: 1 V or less (at 100 mA sink current)
Produktnamn Ultra High-speed・High-precision Laser Displacement Sensor HL-C2
Tidsingång NPN open-collector transistor- ON at / during connection to Common (-)(depending on analysis mode)- Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
Samplingsfrekvens 10 micro s, 20 micro s, 40 micro s, 100 micro s, 200 micro s, 400 micro s, 1 ms, 2 ms
Strobe-utgång NPN open-collector transistor- Maximum sink current: 100 mA- Applied voltage: 30 V DC or less [between each output and Common(-)]- Residual voltage: 1 V or less (at 100 mA sink current)
USB-gränssnitt USB 2.0 Full-speed (USB 1.1 compatible) compliant
Produktnummer HL-C21C
Matningsspänning 24 V DC plus or minus 10 % including ripple 0.5 V (P-P)
Nollställningsingång NPN open-collector transistor- Zero set is ON when connected with Common (-).- Zero set turns to OFF after continuously connected to Common (-) for one second.- Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
Indikator: Ström Green LED (lights up at power on)
Nuvarande förbrukning 500 mA approx. at 2 sensor heads connected350 mA approx. at 1 sensor head connected(100 mA approx. is additionally required when the mini console is connected)
Indikator: Larm 1 Red LED (lights up when OUT1 can not be measured due to insufficient amount of light)
Indikator: Larm 2 Red LED (lights up when OUT2 can not be measured due to insufficient amount of light)
Laserkontrollingång NPN open-collector transistor- Laser emission is stopped when connected to Common (-).- Laser is emitted immediately after opened.- Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
Minnesändringsingång NPN open-collector transistor- Memory is specified when connected to Common (-).- Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
Anslutningsbart sensorhuvud Number of connectable units: Max. 2 units.
Fjärrlåsingång NPN open-collector transistor- Laser emission is delayed when connected to Common (-).- Laser emission stops at open- Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
Inställning / datavisning Compact console (optional)
Analog utgång: Ström Current output scale: 4 to 20 mA / F.S (initial value)Output range during normal status: 2 to 24 mAOutput at abnormal status: 1 mA or 25 mAResolution: 3 micro A, Linearity plus or minus 0.05% F.S.Load impedance: 250 Ohm max.Response delay time: 10 micro s approx.(Note) The linearity is F.S.=16 mA to digital measurement value. Response delay time is the period after update of measurement value.
Analog utgång: Spänning Voltage output scale: -5 to +5 V / F.S (initial value)Output range during normal status: -10.0 to +10.0 VOutput at abnormal status: -10.8 V or +10.8 VResolution: 2 mVLinearity: plus or minus 0.05 % F.S.Max. 2 mA, output impedance 50 OhmResponse delay time: 1.5 micro s / V approx.(Note) The linearity is F.S.=20 V to digital measurement value. Response delay time is the period after update of measurement value.
Bedömningsutgång (HI, GO, LO) NPN open-collector transistor- Maximum sink current: 100 mA- Applied voltage: 30 V DC or less [between each output and Common(-)]- Residual voltage: 1 V or less (at 100 mA sink current)
Larmutgång: Utgångsdrift Opened when the amount of light is insufficient
Strobeutgång: Utgångsdrift Opened at data determination
Larmutgång: Kortslutningsskydd Incorporated
Strobeutgång: Kortslutningsskydd Incorporated
Indikator: Sensorhuvud A Laserstrålning Green LED (lights up during or immediately before laser emission of sensor head A)
Indikator: Sensorhuvud B Laserstrålning Green LED (lights up during or immediately before laser emission of sensor head B)
Miljöbeständighet: Omgivande luftfuktighet 35 to 85 %RH
Miljöbeständighet: Stötdämpning 196 m / s2 acceleration (20G approx.) in X, Y, and Z directions for three times each
Miljöbeständighet: Omgivningstemperatur 0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
Bedömningsutgång (HI, GO, LO): Utgångsdrift Opened at output operation
Miljöbeständighet: Vibrationsbeständighet 10 to 55 Hz frequency (period: 1 min.), 0.75 mm 0.030 in amplitude in X, Y and Z directions for 30 min. each
Bedömningsutgång (HI, GO, LO): Kortslutningsskydd Incorporated

Produktbeskrivning

High performance analog laser high resolution controller, HL-C2 series, Ethernet port, analog output ±5V/ 4 - 20mA, NPN digital output
Viktiga funktioner
  • Industriell kvalitet
  • RoHS-kompatibel
  • CE-certifierad
  • 1 års garanti

Produktdokument

Datablad

Tekniska specifikationer och prestandadata

Användarmanual

Installations- och bruksanvisning

Top