Viktiga specifikationer
Punkt: Specifications
Kabel: 0.2 mm24-core cabtyre cable, 2 m6.562 ftlong
Anmärkning: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23℃+73.4℉.
Vikt: Net weight: 55 g approx., Gross weight: 80 g approx.
Leverantörsinformation
PANASONIC
PANASONIC
Produkter: 4316
Skickas vanligtvis inom 2-3 arbetsdagar
Kvalitetsgaranti
Snabb leverans
Teknisk support

Tekniska specifikationer

Parameter Värde
Punkt Specifications
Kabel 0.2 mm24-core cabtyre cable, 2 m6.562 ftlong
Anmärkning Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23℃+73.4℉.
Vikt Net weight: 55 g approx., Gross weight: 80 g approx.
Material Enclosure, Case cover: Polycarbonate, Switch: Polyacetal
Skydd IP40 (IEC)
Artikelnummer FX-551L3-P-C2
Produktnamn Digital Fiber Sensor FX-550L
Svarstid STD: 250 μs or less, LONG: 2 ms or less, U-LG: 4 ms or less, HYPR: 24 ms or less, selectable
Produktnummer FX-551L3-P-C2
Matningsspänning 12 to 24 V DC+10-15% Ripple P-P 10 % or less
Timerfunktion Incorporated with variable OFF-delay / ON-delay / One-shot, switchable either effective or ineffective
Kabelförlängning Extension up to total 20 m65.617 ftis possible with 0.3 mm2, or more, cable.(Condition of CE compliance: less tan 20 m65.617 ft) (however, supply voltage 12 V DC or more)
Stötdämpning 98 m/s2acceleration (10 G approx.) in X, Y and Z directions five times each
Energiförbrukning Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage)ECO mode: 720 mW or less (current consumption 30 mA or less at 24 V supply voltage)
Omgivningstemperatur -10 to +55℃+14 to +131℉(If 4 to 7 units are mounted in cascade: -10 to +50℃+14 to +122℉or if 8 to 16 units are mounted in cascade: -10 to +45℃+14 to +113℉) (No dew condensation or icing allowed), Storage: -20 to +70℃-4 to +158℉
Styrutgång (DO) PNP open-collector transistor• Maximum source current: 50 mA• Applied voltage: 30 V DC or less (between output and +V)• Residual voltage: 2 V or less (Note) (at maximum source current)(Note:)In case of using the cable (cable length 2 m6.562 ft).
Känslighetsinställning 2-point teaching / Limit teaching / Full-auto teaching / Manual adjustment
Vibrationstålighet 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude (10 G max.) in X, Y and Z directions for two hours each
Tillämpliga bestämmelser CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Timerfunktion: Timerperiod 0.1 to 999.9 ms approx., in units of 0.1 ms approx.
Emitterande element (modulerat) Red LED (Peak emission wavelength: 660 nm 0.026 mil)
Inställning av känslighet för infallande ljus Incorporated, 4 steps
Kommunikationsutgång (C/Q): Baudhastighet COM3 (230.4 kbps)(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Styrutgång (DO): Utgångsdrift Switchable either Light-ON or Dark-ON by L/D mode
Visningsområde för infallande ljusintensitet STD: 0 to 4,000, LONG: 0 to 8,000, U-LG / HYPR: 0 to 9,999
Kommunikationsutgång (C/Q): Processdata 4 byte(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Styrutgång (DO): Kortslutningsskydd Incorporated
Kommunikationsutgång (C/Q): Minsta cykeltid 1.0 ms(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Kommunikationsutgång (C/Q): IO-Link-kommunikation IO-Link Specification V1.1(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Funktion för att förhindra olika frekvensstörningar Incorporated (up to 4 units). Note that the response time varies depending on the setting.F-1: 0.8 ms or less, F-2: 0.9 ms or less, F-3: 1.0 ms or less, F-4: 1.7 ms or less(Note:)This function increases the hysteresis. Check the sensing condition when using the function.

Produktbeskrivning

FX-550L Series. Amplifier F. Optical, 1 digital output PNP, dual display, IO Link connection, 2m cable
Viktiga funktioner
  • Industriell kvalitet
  • RoHS-kompatibel
  • CE-certifierad
  • 1 års garanti

Produktdokument

Datablad

Tekniska specifikationer och prestandadata

Användarmanual

Installations- och bruksanvisning

Top