| Parameter | Värde |
|---|---|
| 115 V AC ... 240 V AC ±10 % (UL) | |
| Färg | red, yellow, green (multicolor LED) |
| Djup | 132 mm |
| I/O/S | asymmetrical |
| Input | asymmetrical 2 kV (Test Level 3) |
| Bredd | 55 mm |
| stel | 0.2 mm² ... 4 mm² |
| Höjd | 135 mm |
| Produktion | asymmetrical 2 kV (Test Level 3) |
| Signal | asymmetrical 1 kV (Test Level 3) |
| LED-lampan släckt | Supply voltage input AC not present (Off) |
| Spänning | 10 V (Test Level 3) |
| Kommentarer | Criterion B |
| Nedgradering | < 100 V AC (1 %/V) |
| Fungera | Visual operating state display |
| Placera | 3.x |
| flexibel | 0.2 mm² ... 2.5 mm² |
| Frekvens | 50 Hz |
| Uppgångstid | ≤ 1 s (UOut= 10 % ... 90 %) |
| Temporär kod | T4 (-25 ... +70 °C; > 60 °C, Derating: 2,5 %/K) |
| EN 61010-1 | III (≤ 2000 m) |
| Effektivitet | typ. 93.8 % (120 V AC) |
| Kriterium A | Normal operating behavior within the specified limits. |
| Kriterium B | Temporary impairment to operational behavior that is corrected by the device itself. |
| Kriterium C | Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. |
| Spänningsdipp | 70 % |
| styv (AWG) | 24 ... 12 (Cu) |
| Toppfaktor | typ. 1.77 (120 V AC) |
| Huvversion | Polycarbonate |
| Produkttyp | Power supply |
| Monteringsanteckning | alignable: 0 mm horizontally, 30 mm vertically |
| Monteringstyp | DIN rail mounting |
| Obelastad | yes |
| Identifiering | UL/C-UL Listed UL 61010-1 |
| Inrusningsström | < 21 A (25 °C) |
| Bulleremission | EN 55016 |
| Brusimmunitet | Immunity in accordance with EN 61000-6-1 (residential), EN 61000-6-2 (industrial) |
| Produktfamilj | TRIO POWER |
| Ytterligare text | Class 3 |
| EN 61010-2-201 | III (≤ 2000 m) |
| Frekvensområde | 0 kHz ... 2 kHz |
| Resterande krusning | typ. 50 mVPP(with nominal values) |
| Tillstånd | UOut> 21 V DC and IOutN (Contact closed) |
| Artikelrevision | 01 |
| Utsläpp i luften | 8 kV (Test Level 3) |
| Maximal höjd | ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m) |
| Antal faser | 1.00 |
| Positionsmarkering | 3.1 (13), 3.2 (14) |
| Skyddsklass | I |
| Avisoleringslängd | 10 mm (Rigid/flexible/ferrule) |
| Anslutningsmetod | Push-in connection |
| Kontakturladdning | 6 kV (Test Level 3) |
| Kontrollavvikelse | < 1 % (change in load, static 10 % ... 90 %) |
| Apparatens nätsäkring | 10 A internal (device protection) |
| Monteringsläge | horizontal DIN rail NS 35, EN 60715 |
| Antal perioder | 25 periods |
| Utgångseffekt (PN) | 480 W |
| Stöt (operation) | 18 ms, 30g, per spatial direction (IEC 60068-2-27) |
| Omkopplingsspänning | max. 30 V DC (SELV) |
| Skyddskrets | Transient protection; Varistor |
| Typer av signalering | LED DC OK – signal state operation (UN= 24 V DC, IOut= IN) |
| Nuvarande förbrukning | 5.3 A (100 V AC) |
| Grad av förorening | 2 |
| Ingångsspänningsområde | 100 V AC ... 240 V AC -15 % ... +10 % |
| Kortslutningssäker | yes |
| Testfältstyrka | 10 V/m (Test Level 3) |
| Seriekoppling | yes, for increased output voltage (observe SELV limit) |
| Skyddsgrad | IP20 |
| Frekvensområde (fN) | 50 Hz ... 60 Hz ±10 % |
| Lysdioden tänd (röd), ISHORT | UOutOut > 0.9 x IN(On (red), ISHORT) |
| Nätbufferttid | typ. 23 ms (120 V AC) |
| Sidoelementversion | Aluminum |
| Standardbeteckning | Safety of power supply units up to 1100 V (insulation distances) |
| Störningsemission | Interference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial) |
| Lysdioden tänd (grön), DC OK | UOut> 21 V DC and IOutN (On (green), DC OK) |
| Lågspänningsdirektivet | Conformance with Low Voltage Directive 2014/35/EC |
| Standarder/föreskrifter | EN 61000-3-2 |
| Vibration (drift) | 10 Hz ... 50 Hz, amplitude ±0.2 mm (IEC 60068-2-6) |
| Parallellkoppling | yes, for increased efficiency and redundancy |
| Nominell utgångsspänning | 24 V DC |
| Effektfaktor (cos phi) | 0.96 (230 V AC) |
| Urladdningsström till PE | < 3.5 mA |
| Ledningsbunden bulleremission | EN 55016 |
| Standarder/specifikationer | DIN EN 61558-2-16 |
| Nuvarande bärförmåga | max. 100 mA |
| Lysdioden tänd (blinkar rött) OVP | UOUT> OVP (Over voltage protection) (On (flashing red)) |
| Brytarkontakt (potensiell) | OptoMOS |
| Dynamisk boost (IDyn.Boost) | max. 30 A (5 s) |
| Integrerat säkringsskydd | no |
| MTBF (IEC 61709, SN 29500) | > 1400000 h (25 °C) |
| Uteffekt (PDyn. Boost) | max. 720 W (5 s) |
| Återkopplingsspänningsresistans | ≤ 35 V DC |
| Lysdiod tänd (gul), Iout > 90% | UOut> 21 V DC and IOut> 0.9 x IN(On (yellow), IOut> 90% ) |
| Nominellt ingångsspänningsområde | 100 V AC ... 240 V AC |
| Nominell utgångsström (IN) | 20 A |
| Konfiguration av matningssystem | Star network (TN, TT, IT (PE)) |
| Effektförlust nominell belastning max. | < 26.72 W (230 V AC) |
| Elektromagnetisk kompatibilitet | Conformance with EMC Directive 2014/30/EU |
| Inrusningsströmsintegral (I2t) | < 1.091 A2s |
| Typisk nationell nätspänning | 120 V AC |
| Spänningtyp av matningsspänning | AC |
| Omgivningstemperatur (drift) | -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
| Isolationsspänning ingång/utgång | 5.3 kV DC (type test) |
| Installationsavstånd höger/vänster | 0 mm / 0 mm |
| Installationsavstånd topp/botten | 50 mm / 50 mm |
| Maximal effektförlust vid tomgång | < 1.37 W (230 V AC) |
| Minsta effektförlust vid tomgång | < 1.3 W (120 V AC) |
| Miljöskyddsdirektivet | RoHS Directive 2011/65/EU |
| Brandfarlighetsklassificering enligt UL 94 | V0 (Housing, terminal blocks) |
| Minsta nominella effektförlust | < 33.37 W (120 V AC) |
| Omgivningstemperatur (lagring/transport) | -40 °C ... 85 °C |
| Rekommenderad brytare för ingångsskydd | 6 A ... 16 A (Characteristic B, C, D, K or comparable) |
| flexibel med hylsa med plasthylsa | 0.25 mm² ... 2.5 mm² |
| Omgivningstemperatur (testad för starttyp) | -40 °C |
| Inställningsområde för utspänning (USet) | 24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted) |
| flexibel med hylsa utan plasthylsa | 0.25 mm² ... 2.5 mm² |
| Max tillåten relativ luftfuktighet (drift) | ≤ 95 % (at 25 °C, non-condensing) |
| Skydd mot överspänning vid utgången (OVP) | ≤ 35 V DC |