| Parameter | Värde |
|---|---|
| 230 V AC | |
| Djup | 61 mm |
| Input | asymmetrical 2 kV (Test Level 3) |
| Bredd | 18 mm |
| stel | 0.2 mm² ... 2.5 mm² |
| Höjd | 90 mm |
| Produktion | asymmetrical 2 kV (Test Level 3) |
| Spänning | 10 V (Test Level 3) |
| Kommentarer | Criterion A |
| Nedgradering | > 50 °C ... 70 °C (2 % / K) |
| Placera | 1.x |
| flexibel | 0.2 mm² ... 2.5 mm² |
| Frekvens | 50 Hz |
| Uppgångstid | typ. 100 ms (UOut= 10 % ... 90 %) |
| EN 61010-1 | II (≤ 4000 m) |
| EN 62477-1 | III (≤ 2000 m) |
| Effektivitet | > 81.5 % (120 V AC) |
| Kriterium A | Normal operating behavior within the specified limits. |
| Kriterium B | Temporary impairment to operational behavior that is corrected by the device itself. |
| Kriterium C | Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. |
| Spänningsdipp | 70 % |
| styv (AWG) | 24 ... 14 (Cu) |
| Toppfaktor | typ. 3.3 |
| Ingång/Utgång | asymmetrical |
| Produkttyp | Power supply |
| Monteringstyp | DIN rail or direct mounting |
| Obelastad | yes |
| Identifiering | UL 1310 Class 2 Power Units |
| Inrusningsström | typ. 30 A (25 °C) |
| Bulleremission | EN 55016 |
| Brusimmunitet | Immunity in accordance with EN 61000-6-2 (industrial) |
| Produktfamilj | STEP POWER |
| Tillslagstid | typ. 2 s |
| Ytterligare text | Class 3 |
| Frekvensområde | 0 kHz ... 2 kHz |
| Resterande krusning | typ. 80 mVPP |
| Utsläpp i luften | 8 kV (Test Level 3) |
| Horisontell lutning | 1 Div. (DIN 43880) |
| Höljets material | Plastic |
| Maximal höjd | ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m) |
| Antal faser | 1.00 |
| Positionsmarkering | 1.1, 1.2 (L), 1.3, 1.4 (N) |
| Skyddsklass | II (in closed control cabinet) |
| Signaltröskel | > 0.9 x UN(UN= 5 V DC) (LED lights up green) |
| Avisoleringslängd | 10 mm (rigid/flexible/ferrule without plastic sleeve) |
| Anslutningsmetod | Push-in connection |
| Kontakturladdning | 6 kV (Test Level 3) |
| Kontrollavvikelse | < 1.5 % (Static load change 10 % ... 90 %) |
| Apparatens nätsäkring | 1.25 A internal (device protection), slow-blow |
| Monteringsläge | horizontal DIN rail NS 35, EN 60715 |
| Antal perioder | 25 periods |
| Utgångseffekt (PN) | 15 W |
| Stöt (operation) | 18 ms, 30g, per spatial direction (IEC 60068-2-27) |
| Typer av signalering | LED |
| Nuvarande förbrukning | 0.3 A (100 V AC) |
| Grad av förorening | 2 |
| Måttritning | |
| Material för fotspärr | Polyamid |
| Ingångsspänningsområde | 100 V AC ... 240 V AC -15 % ... +10 % |
| Kortslutningssäker | yes |
| Testfältstyrka | 10 V/m (Test Level 3) |
| Seriekoppling | yes, for increased output voltage |
| Skyddsgrad | IP20 |
| Frekvensområde (fN) | 50 Hz ... 60 Hz ±10 % |
| Nätbufferttid | typ. 18 ms (120 V AC) |
| Standardbeteckning | Electrical safety |
| Monteringsanvisningar | alignable: 0 mm horizontally, 30 mm vertically |
| Störningsemission | Interference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial) |
| Lågspänningsdirektivet | Conformance with Low Voltage Directive 2014/35/EC |
| Standarder/föreskrifter | EN 61000-3-2 |
| Vibration (drift) | < 15 Hz, amplitude ±2.5 mm (IEC 60068-2-6) |
| Parallellkoppling | yes, for increasing power and redundancy with diode |
| Nominell utgångsspänning | 5 V DC |
| Urladdningsström till PE | < 0.25 mA |
| Med skyddande beläggning | No |
| Ledningsbunden bulleremission | EN 55016 |
| Standarder/specifikationer | IEC 61010-1 (SELV) |
| MTBF (IEC 61709, SN 29500) | > 2428000 h (25 °C) |
| Återkopplingsspänningsresistans | ≤ 10 V DC |
| Nominell utgångsström (IN) | 3 A |
| Konfiguration av matningssystem | Star network (TN, TT, IT (PE)) |
| Effektförlust nominell belastning max. | < 3.4 W (230 V AC) |
| Elektromagnetisk kompatibilitet | Conformance with EMC Directive 2014/30/EU |
| Inrusningsströmsintegral (I2t) | typ. 0.14 A2s |
| Typisk nationell nätspänning | 120 V AC |
| Spänningtyp av matningsspänning | AC |
| Omgivningstemperatur (drift) | -10 °C ... 70 °C (Derating: > 50 °C; 2 %/K) |
| Isolationsspänning ingång/utgång | 4 kV AC (type test) |
| Installationsavstånd höger/vänster | 0 mm / 0 mm |
| Installationsavstånd topp/botten | 30 mm / 30 mm |
| Maximal effektförlust vid tomgång | < 0.1 W (230 V AC) |
| Minsta effektförlust vid tomgång | < 0.1 W (120 V AC) |
| Miljöskyddsdirektivet | RoHS Directive 2011/65/EU |
| Brandfarlighetsklassificering enligt UL 94 | V0 (Housing, terminal blocks, base latches) |
| Minsta nominella effektförlust | < 3.5 W (120 V AC) |
| Omgivningstemperatur (lagring/transport) | -40 °C ... 85 °C |
| Rekommenderad brytare för ingångsskydd | 6 A ... 16 A (Characteristics B, C, D, K) |
| flexibel med hylsa med plasthylsa | 0.2 mm² ... 1 mm² |
| Omgivningstemperatur (testad för starttyp) | -25 °C |
| flexibel med hylsa utan plasthylsa | 0.5 mm² ... 1.5 mm² |
| Max tillåten relativ luftfuktighet (drift) | ≤ 95 % (at 25 °C, non-condensing) |
| Skydd mot överspänning vid utgången (OVP) | < 10 V DC |
Tekniska specifikationer och prestandadata
Installations- och bruksanvisning