| Parameter | Värde |
|---|---|
| For versions with 6 or 7 connections, it is enough to place one DIN rail adapter centrally per block and place flange elements after every other block. | |
| Notera | The maximum load current of a single clamping unit must not be exceeded. |
| Färg | violet (RAL 4005) |
| Djup | 17.7 mm |
| Bredd | 8.3 mm |
| Höjd | 21.6 mm |
| Resultat | Test passed |
| Spektrum | Service life test category 2, bogie-mounted |
| ASD-nivå | 6.12 (m/s²)²/Hz |
| Frekvens | f1= 5 Hz to f2= 250 Hz |
| Potentialer | 1 |
| Pulsform | Half-sine |
| Revolutioner | 135 |
| Acceleration | 3.12g |
| Produkttyp | Distributor terminal block |
| Monteringstyp | for snapping onto a DIN rail adapter |
| Specifikation | DIN EN 50155 (VDE 0115-200):2018-05 |
| Antal rader | 1 |
| Rotationshastighet | 10 rpm |
| Chockens varaktighet | 18 ms |
| Nominell ström | 17.5 A |
| Nominell spänning | 450 V |
| Öppna sidopanelen | No |
| Testinstruktioner | X-, Y- and Z-axis |
| Artikelrevision | 02 |
| Avisoleringslängd | 8 mm ... 10 mm |
| Exponeringstid | 30 s |
| Tvärsnitt AWG | 26 ... 14 (converted acc. to IEC) |
| Anmärkningar om drift | the blocks can be bridged with one another via the conductor shaft, for corresponding plug-in bridges, see accessories |
| Temperaturcykler | 192 |
| Grad av förorening | 3 |
| Isolerande material | PA |
| Nominell stötspänning | 6 kV |
| Testkraftens börvärde | 1 N |
| Maximal lastström | 22 A |
| Överspänningskategori | III |
| Maximal totalström | 26 A |
| Nominellt tvärsnitt | 1.5 mm² |
| Antal anslutningar | 4 |
| Testspänningens börvärde | 1.89 kV |
| Testlängd per axel | 5 h |
| DIN-skena/fäste | NS 35/NS 15 |
| Nominellt tvärsnitt AWG | 14 |
| Isolerande materialgrupp | I |
| Invändig cylindrisk mätare | A2 / B1 |
| Ledartvärsnitt stelt | 0.14 mm² ... 2.5 mm² |
| Omgivningstemperatur (montering) | -5 °C ... 70 °C |
| Ledarens tvärsnitt/vikt | 0.14 mm² / 0.2 kg |
| Antal stötar per riktning | 3 |
| Omgivningstemperatur (aktivering) | -5 °C ... 70 °C |
| Omgivningstemperatur (drift) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) |
| Antal anslutningar per nivå | 4 |
| Ledartvärsnitt flexibelt | 0.14 mm² ... 1.5 mm² |
| Anslutning enligt standard | IEC 60998-2-2 |
| Tillåten luftfuktighet (drift) | 20 % ... 90 % |
| Ledartvärsnitt, stel [AWG] | 26 ... 14 (converted acc. to IEC) |
| Korttidsström 1,5 mm² | 0.18 kA |
| Korttidsström 2,5 mm² | 0.3 kA |
| Brandfarlighetsklassificering enligt UL 94 | V0 |
| Rökgasens toxicitet NFPA 130 (SMP 800C) | passed |
| Omgivningstemperatur (lagring/transport) | -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) |
| Ledartvärsnitt, flexibelt [AWG] | 26 ... 16 (converted acc. to IEC) |
| Tillåten luftfuktighet (lagring/transport) | 30 % ... 70 % |
| Ytbrännbarhet NFPA 130 (ASTM E 162) | passed |
| Användning av statiskt isoleringsmaterial i kyla | -60 °C |
| Maximal effektförlust vid nominellt tillstånd | 0.56 W |
| Kalorimetrisk värmeavgivning NFPA 130 (ASTM E 1354) | 27,5 MJ/kg |
| Brandskydd för spårfordon (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Brandskydd för spårfordon (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Brandskydd för spårfordon (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Brandskydd för spårfordon (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Specifik optisk densitet för rök NFPA 130 (ASTM E 662) | passed |
| Flexibel ledararea (ändhylsa med plasthylsa) | 0.14 mm² ... 1.5 mm² |
| Relativt temperaturindex för isoleringsmaterialet (Elec., UL 746 B) | 130 °C |
| Ledararea flexibel (ändhylsa utan plasthylsa) | 0.14 mm² ... 1.5 mm² |
| Temperaturindex för isoleringsmaterial (DIN EN 60216-1 (VDE 0304-21)) | 125 °C |
Tekniska specifikationer och prestandadata
Installations- och bruksanvisning