| Parameter | Värde |
|---|---|
| However, depending on the application case and mechanical load, other mounting accessory arrangements can also be selected. | |
| notera | IEC 60947-7-1 only applies to the use of fastening accessories. |
| Färg | black (RAL 9005) |
| Djup | 21.7 mm |
| Vändningar | 135 |
| bredd | 6.2 mm |
| Resultat | Test passed |
| höjd | 28.6 mm |
| Spektrum | Category 2 Electrical Life Check, Trolley Mounted |
| ASD-nivå | 6.12 (m/s²)²/Hz |
| Frekvens | f1= 5 Hz up to f2= 250 Hz |
| Mätplatta | A4 |
| Chockformulär | Semi-sinusoidal |
| Acceleration | 3.12g |
| Produkttyp | Distribution terminal |
| Monteringstyp | Mounting on adapters for mounting on a support rail |
| Märkström | 32 A |
| Artikelgranskning | 02 |
| Antal rader | 1 |
| Öppen sidovägg | no |
| Chockens varaktighet | 18 ms |
| Nominell spänning | 800 V |
| Testinstruktioner | X, Y, and Z axis |
| Rotationshastighet | 10 rpm |
| AWG-storleksavsnitt | 12 |
| Testspecifikation | DIN EN 50155 (VDE 0115-200):2008-03 |
| Isoleringsmaterial | PA |
| Temperaturcykling | 192 |
| Maximal lastström | 38 A (bei 6 mm² Leiterquerschnitt starr) |
| Överspänningskategori | Iii |
| Nominellt tvärsnitt | 4 mm² |
| Antal anslutningar | 2 |
| Dimensionering av impulsspänning | 8 kV |
| Testtid per axel | 5 h |
| Användningstid | 30 s |
| Testspänningens nominella värde | 9.8 kV |
| Isoleringsmaterialgrupp | The |
| Maximal kumulativ ström | The maximum load current of the individual connection points must not be exceeded. |
| Ledartvärsnitt AWG | 24 ... 10 (converted according to IEC) |
| Tvärsnitt av stel ledare | 0.2 mm² ... 6 mm² |
| Standardkompatibel anslutning | IEC 60947-7-1 |
| Omgivningstemperatur (montering) | -5 °C ... 70 °C |
| Ledarens tvärsnitt/vikt | 0.2 mm2/0.2 kg |
| Antal anslutningar per plan | 2 |
| Antal stötar per riktning | 3 |
| Omgivningstemperatur (drift) | -60 °C ... 110 °C (Operating temperature range including self-heating, short-term maximum operating temperature cf. RTI Elec.) |
| Omgivningstemperatur (aktivering) | -5 °C ... 70 °C |
| Flexibelt ledartvärsnitt | 0.2 mm² ... 4 mm² |
| Krav på verifiering av uppvärmning | Temperature rise ≤ 45 K |
| Tillåten luftfuktighet (drift) | 20 % ... 90 % |
| NFPA 130 Rökgiftighet (SMP 800C) | Exceeded |
| Tvärsnitt av solid ledare [AWG] | 20 ... 10 (converted according to IEC) |
| Längden på den sektion som ska skalas | 10 mm ... 12 mm |
| Korttidsströmmotstånd 4 mm² | 0.48 kA |
| Korttidsströmmotstånd 6 mm² | 0.72 kA |
| Insats av kall statisk isolering | -60 °C |
| Flexibel ledares tvärsnitt [AWG] | 24 ... 12 (converted according to IEC) |
| Omgivningstemperatur (lagring/transport) | -25 °C ... 60 °C (for short duration, no longer than 24 h, -60 °C to +70 °C) |
| Brännbarhetsklass enligt UL 94 | V0 |
| Tillåten luftfuktighet (lagring/transport) | 30 % ... 70 % |
| Ytbrännbarhet NFPA 130 (ASTM E 162) | Exceeded |
| Maximal effektförlust under nominella förhållanden | 1.02 W |
| Brandskydd för spårfordon (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Brandskydd för spårfordon (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Brandskydd för spårfordon (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Brandskydd för spårfordon (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| NFPA 130 (ASTM E 662) Specifik optisk densitet hos ångor | Exceeded |
| Flexibelt ledartvärsnitt (plastkabelsko och krage) | 0.2 mm² ... 4 mm² |
| Isoleringsmaterials relativa temperaturindex (elektr., UL 746 B) | 130 °C |
| Flexibel ledararea (kabelsko utan isoleringskrage) | 0.2 mm² ... 4 mm² |
| 2 ledare med identiskt tvärsnitt, flexibel med TWIN-hylsa med plastkrage | 0.5 mm² ... 1 mm² |
Tekniska specifikationer och prestandadata
Installations- och bruksanvisning