| Parameter | Värde |
|---|---|
| Repeated strong short circuits can reduce the melting integral of the integrated safety fuse. | |
| EMC | to |
| Säkring | electronic |
| Djup | 55.6 mm (With 7.5 mm rail) |
| Bredd | 6.2 mm |
| Avkastning | > 98.5% |
| Höjd | 105.8 mm |
| Markant | UL/C-UL Listed UL 508 |
| spänning | < 5V DC (Low State) |
| Höjd över havet | ≤ 3000 m up to 52 °C (amsl) |
| Fuktighet | B |
| Material | PBT |
| Inhägnad | to |
| Skotttyp | E (electronic) |
| Vibration | B |
| Observation | Connection for the signal line tested according to EN 61000-4-4 with 1 kV; If applicable, protective measures should be provided on the client's side |
| Temperatur | to |
| Konstruktion | Rail-mounted, one-piece module |
| Produkttyp | Appliance Protection Switches, Electronic |
| Pulslängd | ≥ 50 ms (High) |
| Spänningsfall | 0.28 V (with 0.5 A) |
| Fuktighetskontroll | 96 h, 95% RH, 40 °C |
| Utgångsström | max. 0.015 A (Short Circuit Resistant) |
| Utgångsspänning | 24 V DC (Error) |
| Produktfamilj | PTCB |
| Anslutningstyp | Push-in connection |
| LED-kanal av | Off (Channel Off) |
| Nominell spänning | 24 V DC |
| Antal poler | 1 |
| Röd LED-kanal | Ignition (Channel Off, Overvoltage, or Active Undervoltage) |
| Dimensionsschema | |
| Förlorad kraft | Typ. 0.1W (no load) |
| Skyddsindex | IP20 |
| Märkström IN | 15 A DC (Total Input Current) |
| Regler/Bestämmelser | EN 61000-6-2 |
| Överspänningsavstängning | ≥ 30.5 V DC (active) |
| Typ av montering | Symmetrical rail: 35 mm |
| Felsäkert element | 4 A DC |
| Grön LED-kanal | On (Channel Connected) |
| Driftspänning | 10 V DC ... 30 V DC |
| Försäkring krävs | It is only necessary if IMaxof the power supply is > the ability to short circuit. Built-in safety feature. |
| Strömabsorption | Typ. 0.4 mA (with 24 V DC) |
| Frånkopplingstid | ≤ 600 ms |
| Typ av skydd | Iii |
| Antal kanaler | 1 |
| Viloström I0 | Typ. 3.8 mA |
| Gul LED-kanal | flashes (Programming Mode On) |
| Grad av förorening | 2 |
| Dielektrisk styrka | max. 35 V DC (Charging circuit) |
| Ingångsspänningsområde | 7 V DC ... 30 V DC (Downside Reset) |
| Krascher (i drift) | 30g (IEC 60068-2-27, Ea test) |
| Max kapacitiv belastning | 5.7 mF (Depending on current setting and available short-circuit current) |
| Temperaturnedklassning | 15 A (Total current at 60°C) |
| AWG-ledarsektion | 24 ... 12 |
| Märkström (förinställd) | 0.5 A |
| Vibration (i drift) | 10 Hz ... 59.6 Hz (Amplitude ±0.35 mm; according to IEC 60068-2-6, Fc test) |
| Aktiv strömbegränsning | Typ. 1.1 x IN |
| Mättolerans I | ± 7% |
| Stel ledarsektion | 0.2 mm² ... 2.5 mm² |
| Underspänningsavkoppling | ≤ 9.2 V DC (active) |
| Recirkulationsmotstånd | max. 35 V DC |
| Längd som ska avisoleras | 8 mm |
| Flexibel ledarsektion | 0.2 mm² ... 2.5 mm² |
| MTBF (IEC 61709, SN 29500) | 27129679 h (at 25°C at 21% load) |
| Modulens initialiseringstid | 40 ms |
| Omgivningstemperatur (service) | -30 °C ... 60 °C |
| Dimensionering av transientspänning | 0.5 kV |
| Kapacitet för kortslutningsavbrott | 300 A |
| Brandfarlighetsklass enligt UL 94 | V-0 |
| Timeout efter att en kanal har kopplats bort | 5 sec (in overload/short circuit) |
| Omgivningstemperatur (förvaring/transport) | -40 °C ... 70 °C |
| Flexibel ledarsektion med tåhätta, med plasthylsa | 0.25 mm² ... 2.5 mm² |
| Flexibel ledarsektion med tåhätta, utan plasthylsa | 0.25 mm² ... 2.5 mm² |
Tekniska specifikationer och prestandadata