| Parameter | Värde |
|---|---|
| 8 | |
| Typ | Lower housing parts with vents, housing cover necessary to complete the module |
| Djup | 107.3 mm |
| Tvinga | 20 N |
| Bredd | 45.2 mm |
| Höjd | 99 mm |
| Amplitud | 0.15 mm (10 Hz ... 58.1 Hz) |
| Frekvens | 10 - 150 - 10 Hz |
| Pulsform | Half-sine |
| Svephastighet | 1 octave/min |
| Temperatur | 850 °C |
| Acceleration | 2g (58.1 Hz ... 150 Hz) |
| Bostadstyp | DIN rail housing |
| Monteringsanteckning | Refer to the data sheet for the range in the download area. |
| Monteringstyp | DIN rail mounting |
| Specifikation | IEC 60068-2-6:2007-12 |
| Testets varaktighet | 1 h |
| Fallhöjd | 50 cm |
| Rekommendation | Material of contact pads for bus connector, galvanic gold (hard gold) |
| Chockens varaktighet | 11 ms |
| Testinstruktioner | X-, Y- and Z-axis |
| Höljets material | Polyamide |
| Reduktionsfaktor | 1 |
| Exponeringstid | 30 s |
| Monteringsläge | vertical |
| Effektförlust | 8.2 W |
| Typ av kretskortsmontering | Latching |
| Typ av förpackning | packed in cardboard |
| Omgivningstemperatur | 20 °C |
| Antal positioner | 32 |
| Typ av ytterförpackning | Carton |
| Antal kretskortshållare | 2 |
| Max IP-kod att uppnå | IP20 |
| Testlängd per axel | 2.5 h |
| Ventilationsöppningar finns | yes |
| Antal stötar per riktning | 3 |
| Omgivningstemperatur (drift) | -40 °C ... 105 °C |
| Djup från DIN-skenans överkant | 99.8 mm |
| Brandfarlighetsklassificering enligt UL 94 | V0 |
| Djup från DIN-skenans överkant till stödpunkt på övre del | 68.5 mm |
Tekniska specifikationer och prestandadata