Servicetider: måndag till fredag ​​9:00-18:00
LS-H901-Y - LS-H901-Y PANASONIC Sensor head, retro reflective, range 1m, cable 2m, without reflector
I lager Het produkt

LS-H901-Y

LS-H901-Y PANASONIC Sensor head, retro reflective, range 1m, cable 2m, without reflector

$0.00 USD
i lager
Viktiga specifikationer
Punkt: Specifications
Kabel: 0.15 mm22-core two parallel shielded cables, 2 m 6.562 ft long(Note:Cable cannot be extended.)
Vikt: Net weight: 50 g approx.Gross weight: 85 g approx.
Detaljer: Sensor heads(Coaxial retroreflective type)
Leverantörsinformation
PANASONIC
PANASONIC
Produkter: 4316
Skickas vanligtvis inom 2-3 arbetsdagar
Kvalitetsgaranti
Snabb leverans
Teknisk support

Tekniska specifikationer

Parameter Värde
Punkt Specifications
Kabel 0.15 mm22-core two parallel shielded cables, 2 m 6.562 ft long(Note:Cable cannot be extended.)
Vikt Net weight: 50 g approx.Gross weight: 85 g approx.
Detaljer Sensor heads(Coaxial retroreflective type)
Produkt Amplifier-separated Type Digital Laser Sensor
Material Enclosure: PBTIndicator cover: PolycarbonateBeam-emitting / receiving surfaces: Glass
Åtföljande MS-LS-1(Mounting bracket): 1pc.RF-330(Refrector): 1pc.
Punktstorlek Approx. dia. 6 mm dia. 0.236 in or less (at a distance from the sensor head of 1 m 3.281 ft)
Skydd IP40 (IEC)
Artikelnummer LS-H901-Y
Produktnamn Amplifier-separated Type Digital Laser Sensor LS-500
Produktnummer LS-H901-Y
Avkännande objekt Opaque, translucent, or transparent object(Note:Make sure to confirm detection with an actual sensor before use.)
Omgivande luftfuktighet 35 to 85 % RH, Storage: 35 to 85 % RH
Stötdämpning 100 m / s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Avkänningsområde: HYPR 0.01 to 2.5m0.033 to 8.202 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Avkänningsområde: U-LG 0.01 to 2m0.033 to 6.562 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Omgivande belysningsstyrka Incandescent light: 3,000 ℓx or less at the light-receiving face
Omgivningstemperatur -10 to +55degrees + 14 to + 131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70degrees -4 to +158 degrees Fahrenheit
Driftsindikator Orange LED (lights up when the amplifier output is ON)
Vibrationstålighet 10 to 500 Hz frequency, 1.5 mm0.059 indouble amplitude in X, Y and Z directions for two hours each
Tillämpliga förstärkare LS-501(P), LS-501(P)-C2(Note:When using the thru-beam typeLS-H101□orLS-H102□, do not set the receiving light sensitivity (gctL) of the applicableLS-500series amplifier to level 2 or less. This is because there is a possibility of sensing becoming unstable.)
Emitterande element: Typ Red semiconductor laser diode
Isoleringsmotstånd 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Avkänningsområde: STD-läge 0.01 to 1m0.033 to 3.281 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Avkänningsområde: FAST-läge 0.01 to 1m0.033 to 3.281 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Avkänningsområde: H-SP-läge 0.01 to 1m0.033 to 3.281 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Avkänningsområde: U-LG-läge 0.01 to 1.5m0.033 to 4.921 ft(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Spänningshållbarhet 1,000 V AC for one min. between all supply terminals connected together and enclosure
Emitterande element: Laserklass Class 1 [IEC / JIS / FDA](Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and )Radiological Health) under the FDA (Food and Drug Administration).
Emitterande element: Max. uteffekt 1mW
Överensstämmelse med CE-märkningsdirektivet EMC Directive, RoHS Directive
Emitterande element: Toppemissionsvåglängd 660 nm 0.026 mil

Produktbeskrivning

More details
Viktiga funktioner
  • Industriell kvalitet
  • RoHS-kompatibel
  • CE-certifierad
  • 1 års garanti

Produktdokument

Datablad

Tekniska specifikationer och prestandadata

Användarmanual

Installations- och bruksanvisning