Servicetider: måndag till fredag ​​9:00-18:00
HLC1CM - HLC1CM HL-C1C-M PANASONIC Driver for connecting 2 sensor heads HL-C1 series
I lager Het produkt

HLC1CM

HLC1CM HL-C1C-M PANASONIC Driver for connecting 2 sensor heads HL-C1 series

$0.00 USD
i lager
Viktiga specifikationer
Punkt: Specifications
Vikt: Net weight: 300 g approx.
Detaljer: Controller
Produkt: Ultra High-speed Laser Displacement Sensor [CCD Style]
Leverantörsinformation
PANASONIC
PANASONIC
Produkter: 4316
Skickas vanligtvis inom 2-3 arbetsdagar
Kvalitetsgaranti
Snabb leverans
Teknisk support

Tekniska specifikationer

Parameter Värde
Punkt Specifications
Vikt Net weight: 300 g approx.
Detaljer Controller
Produkt Ultra High-speed Laser Displacement Sensor [CCD Style]
Åtföljande -
Artikelnummer HL-C1C-M
Larmutgång Photo-MOS relay- Maximum load current: 50 mA- Applied voltage: 30 V DC or less (between alarm output and COM)- ON impedance: 35 Ohm or less- Operation time: Max. 2 ms
Kabellängd Power line: Less than 10 m 32.808 ftSignal line: Less than 30 m 98.425 ft
Produktnamn Ultra High-speed Laser Displacement Sensor HL-C1(Discontinued)
Samplingsfrekvens Selectable from 100 micro s / 144 micro s / 200 micro s / 255 micro s / 332 micro s / 498 micro s / 1,000 micro s
Hold-funktioner Selectable from NORMAL / P-P / PEAK / VALLEY(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Produktnummer HL-C1C-M
Matningsspänning 24 V DC plus or minus 10 % including ripple 0.5 V (P-P)
Digitala filter High pass: OFF, 10 to 2,000 Hz (9 steps)Low pass: OFF, 10 to 2,000 Hz (9 steps)(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Indikatorer: MÖRK Red LED (lights up upon disabled measurement due to insufficient light at sensor head 1 or 2)
Nollställning PÅ-ingång Zero set: ON when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input
Kalibrering: Spannmål 0.9000 to 1.1000(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Nollställning AV-ingång Zero set: OFF when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input
Kalibrering: Skift plus or minus 20.0000 mm plus or minus 0.787 in(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Nuvarande förbrukning When 1 sensor is connected: 430 mA approx.When 2 sensors are connected: 550 mA approx.
Indikatorer: LJUS Red LED (lights up upon disabled measurement due to excessive light at sensor head 1 or 2)
Beräkningsfunktioner L plus or minus KA, L plus or minus KB, L plus or minus K (A plus or minus B)A, B: Sensor head 1, Sensor head 2 measurement values, L = plus or minus 999.9999, K = 0.0001 to 99.9999(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Seriell ingång/utgång RS-232C
Anslutningsbart sensorhuvud Maximum 2 sensor heads
Analog utgång: Ström Output current: 4 to 20 mA/F.S. [default setting when diffuse reflective mode is selected (Note 2)]Output range: 0 to 29.5 mA (maximum of 25 mA at max. load impedance)Load impedance: 250 Ohm or less(Note 1) The maximum analog output current will vary with load impedance.(Note 2) If specular reflective mode is selected, then the default setting is 5.6 to 18.4 mA/F.S.
Analog utgång: Spänning Output voltage: plus or minus 5 V/F.S. [default setting when diffuse reflective mode is selected (Note) ]Output range: -10.9 to +10.9 VOutput current: Max. 2 mA, Output impedance: 50 Ohm(Note) If specular reflective mode is selected, then the default setting is plus or minus 4 V/F.S.
Genomsnittligt antal prover OFF, 2 to 32,768 times (16 steps)(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Bedömningsutgångar (O1, O2) Photo-MOS relay- Maximum load current: 50 mA- Applied voltage: 30 V DC or less (between judgment output and COM)- ON impedance: 35 Ohm or less- Operation time: Max. 2 ms
Indikatorer: Laseremission Green LED (lights up during laser emission from sensor head 1 or sensor head 2, or immediately before laser emission)
Temperaturegenskaper plus or minus 0.01 % F.S./degrees
Tidsingång (laseremission) Laser emission stops or continues when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input or there is an open circuit: determined based on input mode selection.
Larmutgång: Utgångsdrift Opened when the amount of light is excessive or insufficient.
Larmutgång: Kortslutningsskydd Incorporated
Miljöbeständighet: Omgivande luftfuktighet 35 to 85 % RH, Storage: 35 to 85 % RH
Miljöbeständighet: Stötdämpning 196 m/s2 (20 G approx.) in X, Y and Z directions for 3 times each
Bedömningsutgångar (O1, O2): Utgångsdrift Opened or closed when the threshold value is reached. Determined based on judgment output mode selection. (The threshold value varies with the hysteresis setting.)
Miljöbeständighet: Omgivningstemperatur 0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
Miljöbeständighet: Vibrationsbeständighet 10 to 55 Hz frequency (period: 1 min.) 0.75 mm 0.030 in amplitude in X,Y and Z directions for 30 min. each
Bedömningsutgångar (O1, O2): Användningskategori DC-12 or DC-13
Bedömningsutgångar (O1, O2): Kortslutningsskydd Incorporated

Produktbeskrivning

More details
Viktiga funktioner
  • Industriell kvalitet
  • RoHS-kompatibel
  • CE-certifierad
  • 1 års garanti

Produktdokument

Datablad

Tekniska specifikationer och prestandadata

Användarmanual

Installations- och bruksanvisning

Top