| Parameter | Värde |
|---|---|
| GTIN | 4046356095389 |
| Notera | Made to Order (non-returnable) |
| Ordernyckel | 1637171 |
| Katalogsida | Page 551 (C-4-2015) |
| Förpackningsenhet | 1 pc |
| Ursprungsland | DE (Germany) |
| Anpassat tariffnummer | 85366990 |
| (Omgivningsförhållanden) | 16 mm (40 mm²) |
| Kontaktmaterial (allmänt) | Copper alloy |
| Märkström (mått) | 200 A |
| Bredd (viktiga kommersiella data) | 34.2 mm |
| (Standarder och föreskrifter) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Höjd (viktiga kommersiella data) | 60 mm |
| Längd (nyckelinformation för affärer) | 29.4 mm |
| Anslutningsprofil (mått) | 1 |
| Nominell stötspänning (mått) | 8 kV |
| Kontaktbärarmaterial (allmänt) | PC |
| Kontaktytans material (allmänt) | Ag |
| Märkspänning (III/3) (Mått) | 1000 V |
| Serie (mekaniska egenskaper) | HC-M-HS |
| Vikt per styck (exklusive emballage) | 69.200 g |
| Sexkantshylsa (omgivningsförhållanden) | WAF 5 |
| Kinas RoHS (standarder och föreskrifter) | Environmentally Friendly Use Period = 50 |
| Åtdragningsmoment (omgivningsförhållanden) | 8 Nm (25 mm² ... 35 mm²) |
| Anslutning (mekaniska egenskaper) | Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Use of cables with a geometric cross section very different from the cable's nominal cross section should be checked before use.The wiring space of the axial screw method is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) should be checked before use.ConnectionBefore starting to connect, ensure that the tapered screw is turned back all the way (chamber is open). The cables must not be twisted. The wires should be inserted as far as they will go in the contact chamber (until the insulation touches the contact). Hold wires in position and use socket wrench to tighten. The used wire end should be cut off before connecting again. The connection screw may only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable should be mechanically intercepted at an appropriate distance from the connection point (e.g., by using a plate cutout). DIN VDE 0100-520:2003-06 contains information on how to do this correctly. The module cannot be used simultaneously with the HC-B..-TMB-SD-IP65 and HC-B..-TMS-SD-IP65 protective covers. |
| Minsta höjd på bostaden (omgivningsförhållanden) | 72 mm |
| Ledarens tvärsnitt (omgivningsförhållanden) | 25 mm² ... 40 mm² (The cross section specification refers to the geometric cross section of the cable used) |
| Anslutningsmetod (mekaniska egenskaper) | Axial screw connection |
| Anslutning enligt standard (Materialdata) | UL |
| Föroreningsgrad (mekaniska egenskaper) | 3 |
| Insättnings-/utdragningscykler (omgivningsförhållanden) | ≥ 500 |
| Anslutningstvärsnitt AWG (omgivningsförhållanden) | 3 ... 2 |
| Överspänningskategori (mekaniska egenskaper) | III |
| Monteringsanvisning (mekaniska egenskaper) | - Use only flexible conductors,- Connection of wires with 5 mm an Allen wrench,- Housing height h ≥ 72 mm,- Connectors may only be operated without load/voltage. |
| Antal modulplatser (mekaniska egenskaper) | 2 |
| Brandfarlighetsklassificering enligt UL 94 (Materialdata) | V0 |
| Tråddiameter inklusive isolering (omgivningsförhållanden) | 12 mm (25 mm²) |
| Omgivningstemperatur (drift) (Elektriska egenskaper) | -40 °C ... 125 °C |
| Avisoleringslängd för den enskilda tråden (omgivningsförhållanden) | 16 mm |
| Brandfarlighetsklassificering enligt UL 94 (mekaniska egenskaper) | V0 |
Tekniska specifikationer och prestandadata
Installations- och bruksanvisning