HC-HS 2-D7-EBUS - HC-HS 2-D7-EBUS 1586264 PHOENIX CONTACT Contact insert
I lager Het produkt

HC-HS 2-D7-EBUS

HC-HS 2-D7-EBUS 1586264 PHOENIX CONTACT Contact insert

$35.46 USD
i lager
Viktiga specifikationer
: Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Typ: D7
Tester: DIN VDE 0627/86
Bredd: 21 mm
Leverantörsinformation
Produkter: 0
Skickas vanligtvis inom 2-3 arbetsdagar
Kvalitetsgaranti
Snabb leverans
Teknisk support

Tekniska specifikationer

Parameter Värde
Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Typ D7
Tester DIN VDE 0627/86
Bredd 21 mm
Höjd 34.8 mm
Längd 21 mm
Serie HC-HS
Allmän for HC-D7 housing, axial connection 2.0 mm, Allen key
Ansökan Power
Produkttyp Contact insert with a fixed no. of positions
Monteringsanteckning To ensure correct use, installation in housing with IP54 protection or better is required
Märkström 40 A
Artikelrevision 04
Kontaktdiameter 4 mm
Kontaktmaterial Copper alloy
Sexkantig hylsa SW2,0
Kontaktnummerering 1 - 2
Åtdragningsmoment 0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing)
Anslutningsprofil 2+PE
Grad av förorening 3
Måttritning
Antal positioner 2
Nominell stötspänning 6 kV
Överspänningskategori III
Anslutningsteknik Axial screw connection
Kontaktmaterialtyp turned
Antal strömkontakter 2
Märkspänning (III/3) 400 V
Ledarens tvärsnitt 4 mm² ... 10 mm² (The cross section specification refers to the geometric cross section of the cable used)
Kontaktbärarmaterial PC
Kontaktytans material Ag
Insättnings-/uttagningscykler ≥ 500
Anslutningstvärsnitt AWG 10 ... 8
Omgivningstemperatur (drift) -40 °C ... 125 °C (including heating up of contacts)
Anslutning enligt standard IEC / EN
Konstruktions- och provningsföreskrifter DIN VDE 0627/86
Brandfarlighetsklassificering enligt UL 94 V0
Avisoleringslängden för den enskilda tråden 8 mm +1 mm

Produktbeskrivning

Contact insert, number of poles: 2+PE, size: D7, power contacts: 2, Female, Axial screw connection, 400 V, 40 A, 4 mm² ... 10 mm², Application: Power
Viktiga funktioner
  • Industriell kvalitet
  • RoHS-kompatibel
  • CE-certifierad
  • 1 års garanti

Produktdokument

Datablad

Tekniska specifikationer och prestandadata

Användarmanual

Installations- och bruksanvisning