| Parameter | Värde |
|---|---|
| PoDL Power Class 11 | |
| MTTF | 185.12 Years (SN 29500 standard, temperature 25 °C, duty cycle 21%) |
| Djup | 119 mm |
| Bredd | 45 mm |
| Höjd | 130 mm |
| Allmän | Telephone and on-site support (for a fee) |
| Förvaltning | Web-based management (HTTP/HTTPS) |
| Redundans | MRP (Media Redundancy Protocol) |
| Signal-LED:er | Data Receiving, Link Status |
| Konstruktion | Sample book |
| Produkttyp | Switch |
| Signalfördröjning | ≥ 1.9 μs (Store-and-Forward mode, 10/100/1000 MBit/s, depending on frame size) |
| Testspänning | 500 V DC |
| Hamnsäkerhet | MAC-based, RADIUS (IEEE 802.1X), MAC Authentication Bypass |
| Produktfamilj | Managed Switch 2000 |
| Skalmaterial | Fiber-reinforced polycarbonate |
| Matningsspänning | 20 V DC ... 32 V DC |
| Anslutningstyp | RJ45 |
| Lokal diagnos | US1/2 Supply Voltage US1, US2 Green LED |
| Andra funktioner | MMS & GOOSE Transmission (IEC 61850-8-1) |
| Resterande krusning | 3.6 VPP(within the permissible voltage range) |
| Dimensionsschema | |
| Filterfunktioner | Quality of Service (8 priority classes) |
| Strömanslutning | via COMBICON, max. conductor cross-section 1.5 mm² |
| Skyddsindex | IP20 |
| Specialfunktioner | Extended temperature range, Single Pair Ethernet ports with PoDL |
| Typ av montering | Rail mounting |
| MAC-adresstabell | 8k |
| Energiförbrukning | 65 W (Vin= max, tAMB= Max, IPSE= 8x IPoDLmax, 100% data traffic on all connected ports) |
| Statusindikering | LEDs: US1, US2 (Power Supply), Fail (Alarm Contact), 2 LEDs for each Ethernet port (Link/Activity and Speed) |
| Verifieringsväg | 1 minute at FE 500 V DC |
| Typ av skydd | III (VDE 0106) |
| Antal kanaler | 3 (RJ45 ports) |
| Överföringshastighet | 10/100/1000 MBit/s |
| Grundläggande funktionalitet | Switch Store and Forward, IEEE 802.3 compliant |
| Grad av förorening | 2 |
| IP-parametrisering | DHCP-Client |
| Matningsspänning (DC) | 24 V DC (Simultaneous PoDL power supply according to IEEE 802.3cg) |
| Sändningslängd | 100 m (per segment) |
| Överföringsmedium | copper |
| Vibration (service) | according to IEC 60068-2-6: 5g, 150 Hz |
| Krascher (i drift) | 30g (EN 60068-2-27) |
| Diagnostiska funktioner | RMON History |
| Tidssynkronisering | SNTP (Simple Network Time Protocol) |
| Transmissionsfysik | copper |
| AWG-ledarsektion | 24 ... 16 |
| Störningsemission | EN 61000-6-4 |
| Lufttryck (service) | 80 kPa ... 110 kPa up to 2000 m above sea level (No derating) |
| Störningsmotstånd | EN 61000-6-2 |
| Stel ledarsektion | 0.25 mm² ... 1.5 mm² |
| Längd som ska avisoleras | 9 mm |
| PROFINET-konformitetsklass | Conformance-Class B |
| Flexibel ledarsektion | 0.25 mm² ... 1.5 mm² |
| Maximal strömabsorption | 2.2 A (Us= Min, TAMB= Max, SPE = 8x max. PoDL Power, 100% data traffic on all connected ports) |
| Typisk strömabsorption | 1.03 A (to Us= Nom, TAMB= 25°C, SPE = 4x max. PoDL Power, 100% data traffic on all connected ports) |
| Omgivningstemperatur (service) | -40 °C ... 70 °C |
| Elektromagnetisk kompatibilitet | Compliance with EMC Directive 2014/30/EU |
| Överensstämmelse med EMC-direktiv | EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B |
| Anmärkning om anslutningstypen | Autonegoation and Autocrossing |
| PROFINET-modulens funktion | PROFINET Device |
| Lufttryck (förvaring/transport) | 79 kPa ... 108 kPa up to 2000 m above sea level (No derating) |
| Status och diagnostiska indikationer | LEDs: US1, US2 (Power Supply), Fail (Alarm Contact), 2 LEDs for each Ethernet port (Link/Activity and Speed) |
| Tillåten luftfuktighet (drift) | 10 % ... 95% (non-condensing) |
| Omgivningstemperatur (förvaring/transport) | -40 °C ... 85 °C |
| Tillåten luftfuktighet (lagring/transport) | 10 % ... 95% (non-condensing) |
| Fri från störande lackvätande ämnen | Yes |
| Maximal förlusteffekt vid nominellt tillstånd | 12 W (Vin= max, tAMB= Max, IPSE= 8x IPoDLmax, 100% data traffic on all connected ports) |
Tekniska specifikationer och prestandadata