| Parameter | Värde |
|---|---|
| Aluminum/Sheet Steel DC01 | |
| MTTF | 87.5 Years (MIL-HDBK-217F Standard, Temperature 25°C, 100% Operating Cycle) |
| Plugg | Yes |
| Djup | 90 mm |
| Bredd | 22.5 mm |
| Höjd | 123 mm |
| Höjd över havet | 2000 m (maximum) |
| Signal-LED:er | Data Receiving, Link Status |
| Produkttyp | Switch |
| EMC-indikation | EMC: Class A product, see manufacturer's statement in the download center |
| Produktfamilj | Unmanaged Switch 1000 |
| Skalmaterial | Fiber-reinforced polycarbonate |
| Matningsspänning | 9 V DC ... 32 V DC |
| Anslutningstyp | RJ45 |
| Andra funktioner | 100 BASE-TX/100BASE-FX (IEEE 802.3U) |
| Resterande krusning | 3.6 VPP(within the permissible voltage range) |
| Strömanslutning | Through COMBICON, max. conductor cross-section 2.5 mm² |
| Skyddsindex | IP30 |
| Typ av montering | Rail mounting |
| UL, USA / Kanada | UL 61010-1, UL 61010-2-201, UL 62368-1Class I, Div. 2, Groups A, B, C, D, T4Class I, Zone 2, Group IIC, T4 |
| MAC-adresstabell | 4K |
| Statusindikering | LEDs: Us, liaison and activity by port |
| Antal kanaler | 4 (RJ45 ports) |
| Överföringshastighet | 10/100/1000 MBit/s |
| Grundläggande funktionalitet | Unmanaged Switch |
| Matningsspänning (AC) | 24 V AC (50/60 Hz) |
| Matningsspänning (DC) | 24 V |
| Sändningslängd | 100 m (per segment) |
| Överföringsmedium | copper |
| Vibration (service) | according to IEC 60068-2-6: 5g, 150 Hz |
| Krascher (i drift) | 30g (EN 60068-2-27) |
| Antal gränssnitt | 4 |
| Transmissionsfysik | Ethernet on RJ45-twisted pair |
| AWG-ledarsektion | 24 ... 12 |
| Störningsemission | EN 61000-6-4:2007 + A1:2011 |
| Lufttryck (service) | 79 kPa ... 108 kPa up to 2000 m above sea level (No derating) |
| Valörsanslutning | Power supply |
| Störningsmotstånd | EN 61000-6-2:2005 |
| Stel ledarsektion | 0.2 mm² ... 2.5 mm² |
| Längd som ska avisoleras | 10 mm |
| Flexibel ledarsektion | 0.2 mm² ... 2.5 mm² |
| Maximal strömabsorption | 425 mA (with 9 V DC) |
| Typisk strömabsorption | 47 mA (with 24 V DC) |
| Omgivningstemperatur (service) | -40 °C ... 75 °C |
| Elektromagnetisk kompatibilitet | Compliance with EMC Directive 2014/30/EU |
| Överensstämmelse med EMC-direktiv | EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B |
| Anmärkning om anslutningstypen | Autonegoation and Autocrossing |
| Status och diagnostiska indikationer | LEDs: Us, liaison and activity by port |
| Tillåten luftfuktighet (drift) | 5 % ... 95% (non-condensing) |
| Omgivningstemperatur (förvaring/transport) | -40 °C ... 85 °C |
| Tillåten luftfuktighet (lagring/transport) | 5 % ... 95% (non-condensing) |
| Flexibel ledarsektion med tåhätta, med plasthylsa | 0.25 mm² ... 2.5 mm² |
| Flexibel ledarsektion med tåhätta, utan plasthylsa | 0.25 mm² ... 2.5 mm² |
Tekniska specifikationer och prestandadata
Installations- och bruksanvisning