| Parameter | Värde |
|---|---|
| 2962 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | |
| EMC | B |
| MTBF | 6702 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
| Notera | Please follow the special installation instructions in the documentation! |
| Djup | 53 mm |
| Bredd | 29 mm |
| Höjd | 90 mm |
| Fuktighet | A |
| Inhägnad | Required protection according to the Rules shall be provided upon installation on board |
| Vibration | A |
| CCCex-anteckning | Use in potentially explosive areas is not permitted in China. |
| Certifikat | PxCIF14ATEX2901642U |
| Temperatur | B |
| Produkttyp | Patch panel |
| Monteringstyp | DIN rail mounting |
| Identifiering | II 3 G Ex ec IIC Gc |
| PIN-tilldelning | 1:1 |
| Kabelimpedans | 100 Ω |
| Färg (hölje) | green (RAL 6021) |
| Antal kanaler | 1 |
| Artikelrevision | 09 |
| Anslutningsmetod | Spring-cage connection |
| Material (hölje) | PVC / PA |
| Måttritning | |
| Anmärkning om ansökan | Only for industrial use |
| Sändningslängd | 100 m (including patch cables) |
| Skyddsgrad | IP20 |
| Ytterdiameter för kabeln | 6 mm ... 10 mm |
| Seriell överföringshastighet | 10/100/1000 Mbps |
| Insättnings-/uttagningscykler | ≤ 2500 |
| Omgivningstemperatur (montering) | -10 °C ... 70 °C |
| Omgivningstemperatur (drift) | -25 °C ... 70 °C |
| Tillåten luftfuktighet (drift) | 25 % ... 95 % (non-condensing) |
| Enkeltrådig/kopplingspunkt, flexibel | 0.2 mm² ... 1 mm² |
| Enkelledare/kopplingspunkt, stel | 0.2 mm² ... 1.5 mm² |
| Omgivningstemperatur (lagring/transport) | -25 °C ... 85 °C |
| Entrådig/terminalpunkt, styv AWG max. | 16 |
| Entrådig/kopplingspunkt, styv AWG min. | 24 |
Tekniska specifikationer och prestandadata