| Parameter | Värde |
|---|---|
| 599 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) | |
| EMC | B |
| MTBF | 492 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
| MTTF | 1400 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
| Notera | Please follow the special installation instructions in the documentation! |
| Djup | 114.5 mm |
| Input | ± 2 kV (Test Level 3) |
| Bredd | 22.5 mm |
| Höjd | 99 mm |
| Signal | Ethernet |
| Spänning | 10 V |
| Höjd över havet | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) |
| Kommentarer | Criterion B |
| Fuktighet | A |
| Inhägnad | Required protection according to the Rules shall be provided upon installation on board |
| Vibration | A |
| CCCex-anteckning | Use in potentially explosive areas is not permitted in China. |
| Våglängd | 1300 nm |
| Certifikat | CE-compliant |
| Kriterium A | Normal operating behavior within the specified limits. |
| Kriterium B | Temporary impairment to operational behavior that is corrected by the device itself. |
| Fibertyper | 50/125 µm |
| Signal-LED:er | Activity, link status, 10/100 Mbps |
| Temperatur | B |
| Länka genom | Link fault pass through |
| Produkttyp | Media converter |
| Signalfördröjning | ± 1.3 µs (Store and Forward mode, 10/100 Mbps, depending on the frame size) |
| Monteringstyp | DIN rail mounting |
| Identifiering | II 3 G Ex nA IIC T4 Gc X |
| Grundläggande funktioner | Store-and-forward media converter |
| Färg (hölje) | green (RAL 6021) |
| Fältintensitet | 10 V/m |
| Frekvensområde | 80 MHz ... 3 GHz (Test Level 3) |
| Antal kanaler | 1 |
| Artikelrevision | 12 |
| Utsläpp i luften | ± 8 kV (Test Level 3) |
| Avisoleringslängd | 7.00 mm |
| Anslutningsmetod | Plug-in screw terminal block (COMBICON), redundancy possible |
| Kontakturladdning | ± 6 kV (Test Level 3) |
| Åtdragningsmoment | 0.56 Nm ... 0.79 Nm |
| Indirekt utsläpp | ± 6 kV |
| Material (hölje) | PA 6.6-FR |
| Skyddskrets | Reverse polarity protection |
| Överföringshastighet | 10/100 Mbps |
| Måttritning | |
| Anmärkning om ansökan | Only for industrial use |
| Sändningslängd | 100 m (shielded twisted pair) |
| Överföringsmedium | Multi-mode fiberglass |
| Skyddsgrad | IP20 |
| Elektrisk isolering | according to IEEE 802.3 |
| Matningsspänningsområde | 18 V DC ... 30 V DC (Screw connection) |
| MDI-/MDI-X-omkoppling | Auto-MDI(X) |
| Standarder/föreskrifter | EN 61000-4-2 |
| Autoförhandlingslägen | Auto |
| Sändningskapacitet, maximal | ≤ -14 dBm ((50/125 µm) dynamic in link mode (average)) |
| Sändningskapacitet, minst | ≥ -23.5 dBm ((50/125 µm) dynamic in link mode (average)) |
| Typisk strömförbrukning | < 100 mA (24 V DC) |
| Maximal mottagarkänslighet | -14 dBm (dynamic in link mode (average)) |
| Minsta mottagarkänslighet | -31 dBm (dynamic in link mode (average)) |
| Elektromagnetisk kompatibilitet | Conformance with EMC Directive 2014/30/EU |
| Omgivningstemperatur (drift) | -40 °C ... 65 °C |
| Tillåten luftfuktighet (drift) | 5 % ... 95 % (non-condensing) |
| Enkeltrådig/kopplingspunkt, flexibel | 0.2 mm² ... 2.5 mm² |
| Enkelledare/kopplingspunkt, stel | 0.2 mm² ... 2.5 mm² |
| Omgivningstemperatur (lagring/transport) | -40 °C ... 85 °C |
| Ledartvärsnitt, flexibelt [AWG] | 24 ... 14 |
| Tillåten luftfuktighet (lagring/transport) | 5 % ... 95 % (non-condensing) |
| Testspänningsdatagränssnitt/strömförsörjning | 0.5 kVrms(50 Hz, 1 min.) |
| Sändningslängd inkl. 3 dB systemreserv | 6.4 km (F-G 50/125 0.7 dB/km F 1000) |
| Maximal effektförlust vid nominellt tillstånd | 2.4 W |
| Fri från ämnen som kan försämra appliceringen av beläggningen | VDMA 24364:2018-05 |
Tekniska specifikationer och prestandadata
Installations- och bruksanvisning