| Parameter | Värde |
|---|---|
| 134 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) | |
| MTTF | 293 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
| Djup | 115 mm |
| Input | ± 2.2 kV |
| Bredd | 23 mm |
| Höjd | 101 mm |
| Signal | Ethernet |
| Spänning | 10 V |
| Höjd över havet | ≤ 2000 m |
| Kommentarer | Criterion B |
| Material | PA 6.6-FR |
| Nättyp | Permanent line |
| Certifikat | CE-compliant |
| Kriterium A | Normal operating behavior within the specified limits. |
| Kriterium B | Temporary impairment to operational behavior that is corrected by the device itself. |
| Utgångseffekt | ≤ 91 W (With PoL) |
| Produkttyp | Ethernet extenders |
| Monteringstyp | DIN rail mounting |
| Identifiering | ISA-S71.04-1985 G3 Harsh Group A |
| Bulleremission | EN 61000-6-4, Class A, industrial area of application |
| Brusimmunitet | EN 55035 |
| Grundläggande funktioner | Gigabit Ethernet extender in accordance with ITU G.9960 |
| Fältintensitet | 10 V/m |
| Frekvensområde | 80 MHz ... 3 GHz (80% amplitude modulation with 1 kHz) |
| Antal kanaler | 1 |
| Utsläpp i luften | ± 8 kV |
| Föroreningsgrad | 2 |
| Avisoleringslängd | 10 mm |
| Anslutningsmetod | Push-in spring connection |
| Kontakturladdning | ± 6 kV |
| Tvärsnitt AWG | (converted acc. to IEC) |
| Monteringsläge | Vertical (horizontal DIN rail) |
| Energiförbrukning | ≤ 7.5 W (Without PoL, without PoE) |
| Indirekt utsläpp | ± 6 kV |
| Skyddskrets | Overload protection, protection against polarity reversal; Internal device protection: 2x 5 AF, internal series diode |
| Överföringshastighet | ≤ 1000 Mbps (Depending on the quality of the data line) |
| Måttritning | |
| Protokoll som stöds | Protocol-transparent for TCP/IP, IPv4, and IPv6 |
| Sändningslängd | < 100 m (shielded twisted pair) |
| Överföringsmetod | QAM (quadrature amplitude modulation) carrier frequency method |
| Skyddsgrad | IP20 |
| Elektrisk isolering | VCC (US+GND) // Ethernet (PoE) // G.hn (without PoL) // FE |
| Maximal uteffekt | 15 W (at ≤55°C) |
| Matningsspänningsområde | 18 V DC ... 57 V DC |
| Monteringsanvisningar | To allow for air circulation, mount the device freestanding, with a clearance of at least one centimeter on all sides to other devices. |
| Standarder/föreskrifter | EN 61000-4-2 |
| Nominell matningsspänning | 24 V DC (Without PoL, without PoE) |
| Seriell överföringshastighet | 10/100/1000 Mbps |
| Elektromagnetisk kompatibilitet | Conformance with EMC Directive 2014/30/EU |
| Omgivningstemperatur (drift) | -40 °C ... 60 °C (Free standing, without PoE) |
| Tillåten luftfuktighet (drift) | 10 % ... 95 % (non-condensing) |
| Enkeltrådig/kopplingspunkt, flexibel | 0.2 mm² ... 2.5 mm² |
| Brandfarlighetsklassificering enligt UL 94 | V0 |
| Enkelledare/kopplingspunkt, stel | 0.2 mm² ... 2.5 mm² |
| Omgivningstemperatur (lagring/transport) | -40 °C ... 85 °C |
| Ledartvärsnitt, flexibelt [AWG] | 24 ... 16 |
| Tillåten luftfuktighet (lagring/transport) | 10 % ... 95 % (non-condensing) |
| Testspänningsdatagränssnitt/strömförsörjning | 1.5 kV AC (50 Hz, 1 min.) |
| Ledartvärsnitt, flexibelt, med ändhylsa, med plasthylsa | 0.2 mm² ... 2.5 mm² |
| Ledararea flexibel, med ändhylsa utan plasthylsa | 0.2 mm² ... 2.5 mm² |
| 2 ledare med samma tvärsnitt, flexibla, med TWIN-hylsa med plasthylsa | 0.5 mm² ... 1.5 mm² |
Tekniska specifikationer och prestandadata