| Parameter | Värde |
|---|---|
| (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | EW PLUS 961 EO/EW PLUS 961 EO LVD |
| D. I (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | If |
| Modell (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | EW PLUS 971 EO |
| Effekt (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | 230V~ ±10% 50/60Hz |
| Format (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | Panel 74x32 |
| Sonder (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | 2 NTC |
| Reläer (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | 2 |
| Display (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | with decimal point * 3 digits + sign |
| Kopieringskort (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | If |
| Precision (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | better than 0.5% of end of scale + 1 digit |
| Referens (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | EW29DIEXC4780 |
| Mått (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | 74 x 32 x 59 mm |
| Upplösning (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | 1 or 0.1°C |
| Förbrukning (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | 4.5 W max |
| USB Unicard (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | If |
| Anslutning (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | Port TTL for connection to Unicard/Copy Card or to system monitoring TelevisSystem (need Bus Adapter) |
| Analoga ingångar (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | 1 NTC |
| Digital ingång (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | If |
| Displayfält (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | probe NTC: -50,0...110,0°C |
| Energibesparing (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | If |
| Matningsspänning (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | 230VAC |
| Digitala utgångar (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | 1 SPST: 2Hp (12FLA - 72LRA) max 240V |
| Fältmätning (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNINGAR (EW PLUS 961 - 971 - 974 EO LVD)) | -50,0...110,0°C |
| Konfigurerbara ingångar (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | 1 digital (SELV)1 digital (SELV) / serial TTL* |
| Förpackningstillverkare (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | If |
| * valbar via parameter (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | |
| Detektering av underspänning (TERMOSTAT MED DETEKTION AV ÖVERSPÄNNINGAR OCH UNDERSPÄNNINGAR (EW PLUS 961 - 971 - 974 EO LVD)) | No / Yes (only model LVD) |
| EO: Miljöoptimerad (TERMOSTAT MED DETEKTION AV ÖVER- OCH UNDERSPÄNNING (EW PLUS 961 - 971 - 974 EO LVD)) | If |
Tekniska specifikationer och prestandadata